Compare-Detectors
SofTA Corporation offers
Features Rich Detectors for Every Laboratory and Application.
MODEL | LABORATORY | EASE OF USE | PERFORMS WITH | SENSITIVITY | DYNAMIC RANGE | PRICE | |
---|---|---|---|---|---|---|---|
2300 | ![]() |
High Throughput using Ultra Performance or Rapid Resolution LC | Touch Sensitive panel and PC Based Control Program | All solvents and flowrates | Very Highest | 3+ orders of Magnitude |
Competitive |
1300 | ![]() |
High Throughput using Ultra Performance or Rapid Resolution LC | Six button control and CDS Drivers | All solvents and flowrates | Very Highest | 3+ orders of Magnitude |
Competitive |
300s | ![]() |
Advanced Research | Easy, four button control and CDS Driver | All solvents and flowrates | Highly Sensitive | 3 orders of Magnitude |
Very Reasonable |
200s | ![]() |
General Laboratory | Easy, two button control and CDS Driver | Conventional flowrates and organic or aqueous solvents | More Sensitive | 2+ orders of Magnitude |
Affordable |
100 | ![]() |
Quality Control or Educational Laboratory | Easiest, no parameters to modify | Conventional flowrates and mostly organic mobile phases | Sensitive | 2+ orders of Magnitude |
Comparable to UV |
Product Specifications
MODEL 100 | MODEL 200S | MODEL 300S | MODEL 1300 | MODEL 2300 | |
---|---|---|---|---|---|
Dimensions | 9.8″ W x 18″ D x 11.5″ H | 13.7″ W x 17.25″ D x 6.25″ H | 7.5” W x 15” D x 12” H | ||
Weight | 23 lbs | 25 lbs | 46 lbs | 21 lbs | |
Display | 2 Line x 20 Character per line VFD | ||||
User Interface | Two multi-function buttons | Four multi-function buttons or CDS Control | Six multi-function buttons or CDS Control | Touch-sensitive keys, CDS or PC based application control | |
Evaporative Zone Temperature | 60°C | Ambient to 120°C | |||
Thermo-Split™ Chamber Temperature | 30°C | 30°C to 60°C | 10°C to 70°C | 10°C to 60°C | |
Liquid Flow Rate | 0.2mL/min to 3mL/min | 0.2mL/min to 5mL/min | |||
Gas Requirements | 60–80 psi Nitrogen or other inert gas | ||||
Gas Consumption | ~ 2.5 SLPM | ~ 3 SLPM | |||
Operating Conditions | Intended for indoor use only, 60°F to 85°F and <90% R.H. non condensing | ||||
Elictrical Requirements | Nominal 120 VAC, 50/60 Hz or Nominal 240 VAC, 50/60 Hz; 600 watts | ||||
Wetted Materials | Stainless steel, glass, anodized aluminum, Teflon™ | ||||
Light Source | 670 nm Laser Diode, <5mW | ||||
Detector | Hermetically sealed photo-diode/operational amplifier | ||||
Output Signal | 0–5 VDC | 0–1 VDC | |||
Interface | RS232, Contact Closure | USB, Contact Closure |