Specifications
FT/IR-6000 Series Specifications
Model | ||||
Standard wavenumber measurement range | 7,800 to 350 cm-1 | |||
Optional extended wavenumber range | 25,000 to 10 cm-1 | |||
Display wavenumber range | 15,000 to 0 cm-1 (standard), 25,000 to 0 cm-1 (optional) | |||
Wavenumber accuracy | Within ± 0.01 cm-1 (theoretical value) | |||
Maximum resolution | 0.4 cm-1 0.07 cm-1 (optional) |
0.25 cm-1 0.07 cm-1 (optional) |
0.07 cm-1 | |
Optical System | Single beam | |||
Sample chamber | Size: 200 mm (W) × 260 mm (D) × 185 mm Optical path: Center focus, light axis 70 mm high |
|||
Interferometer | Configuration | 28° Michelson interferometer Corner cube mirror interferometer, with auto-alignment mechanism, sealed structure, DSP control |
||
Vacuum instrument | Options available | |||
Mirror coating | Aluminum | Gold | ||
Drive method | Mechanical bearing, electromagnetic drive | |||
Drive speed | 0.5, 1, 2, 3, 4, 5, 6, 7, 8 mm/sec AUTO DLATGS 2.0 mm/sec. MCT (optional) 4.0 mm/sec. |
0.5, 1, 2, 3, 4, 5, 6, 7, 8 mm/sec AUTO DLATGS 2.0 mm/sec. MCT (optional) 4.0 mm/sec. |
0.125, 0.25, 0.5, 1, 2, 3, 4, 5, 6, 7, 8 mm/sec AUTO DLATGS 2.0 mm/sec. MCT (optional) 4.0 mm/sec. |
|
Rapid Scan | 20 Hz (optional) | 20 Hz (standard) | ||
Beam splitter | Substrate material | Standard: Ge/KBr Option: Quartz, Si/CaF2, Ge/CsI, Mylar (interchangeable) |
||
Replacement method | Secure-lock beamsplitter catch system — (Option: Automatic beam splitter exchange system) |
|||
Light source | Standard: High-intensity ceramic source Option: Halogen lamp, water-cooled mercury light source Up to three light sources may be installed simultaneously including external light sourcess |
|||
Detector | DLATGS (with Peltier temperature control) (standard) | |||
W-MCT, M-MCT, N-MCT, Si, InSb, InGaAs, PAS, Si bolometer (optional) Two detectors may be mounted simultaneously within the instrument. Up to two external detectors may be installed. |
||||
Purging | Interferometer, Sample compartment/Detector | |||
Signal-to-noise ratio: (4 cm-1, 1 min, near 2,200 cm-1) |
45,000:1 | 47,000:1 | 55,000:1 | |
Gain switching | AUTO, 1, 2, 4, 8, 16, 32, 64, 128 | |||
100%T line flatness | Within 100 ± 1.0%T (4,000 to 700 cm-1, continuous repetitive measurement) |
|||
Communication | USB 2.0 | |||
FTIR main unit | Dimensions: 600 (W) × 670 (D) × 315 (H) mm Weight:56 kg |
|||
Power supply unit | Dimensions:200 (W) × 285 (D) × 90 (H) mm, Weight:4.7 kg This unit can be placed on its base or on its side. |
Standard Composition
Parts name | Number | Remarks |
Power supply | 1 | |
Connection cable | 1 | Cable for connecting the main unit to the power supply |
AC cable | 1 | AC cable for the power supply |
USB cable | 1 | Cable connecting the main unit to the PC |
Sample holder | 1 | |
Standard sample | 1 | Polystyrene film |
Stepped pin | 2 | Used when installing optional accessories into the sample compartment. |
Instruction manual | 1 | |
Install Disk | 1 | Including Spectra ManagerTM II, QAU-4000 Quantitative program and KnowItAll JASCO Edition |
Fuse | 2 |
* CFR Model does not include QAU-4000.