Specifications

Model MSV-5100 MSV-5200 MSV-5300
Optical System
Double beam single monochromator Czerny-Turner mount
Light Source
30W Deuterium lamp, 20W Halogen lamp
Light Source (Option)
150W Xenon lamp (air-cooled)
Wavelength Range 200 – 900 nm 200 – 2700 nm 200 – 1600 nm
Wavelength Accuracy ± 0.3 nm (656.1 nm)
± 0.3 nm (656.1 nm)
± 1.5 nm (1312.2 nm)
Spectral Bandwidth 1, 2, 5, 10, L2, L5, L10 nm 1, 2, 5, 10, L2, L5, L10 nm (UV/Vis)
4, 8, 20, 40, L8, L20, L40 nm (NIR)
1, 2, 5, 10, L2, L5, L10 nm (UV/Vis)
2, 4, 10, 20, L4, L10, L20 nm (NIR)
Scan Modes
Continuous scan, step scan
Detector PMT PMT
Peltier-cooled PbS
PMT
Peltier-cooled InGaAs
Sample Observation
High resolution CMOS camera (1600 × 1200 pixel), optical zoom, ATOS feature, LED illumination
Sample Observation (Option)
Binocular, polarized observation, objective lens
Objective
Cassegrain objective, ×10, ×16, ×32 selectable *1
Condenser Mirror
Cassegrain collection mirror, ×10, ×16, ×32 user-interchangeable *1
(Automated condenser mirror compensation function)
Aperture
User-selectable dual-aperture settings for circular and rectangular (slit type) apertures
10, 20, 30, 50, 100, 200 µmf (×16 objective)
5, 10, 15, 25, 50, 100 µmf (×32 objective)
16, 32, 48, 80, 160, 320 µmf (×10 objective)
Sample Stage
Manual stage (working area: X 50 × Y 75 × Z 20 mm) *2
Sample Stage (Option)
Auto stage (working area: X 76 × Y 52 × Z 25 mm, 1 µm step) *2, joystick (option)
Polarizer
Glan-Taylor, automatic insertion/angle setting
Analyzer (Option):
Glan-Taylor, automatic insertion/angle setting
Control Panel
Cassegrain switching and indicator, transmittance/reflectance mode indicator, aperture selection,
measurement start/stop, auto focus, automatic condenser mirror compensation, optical zoom,
automated sample illumination, sample compartment illumination ON/OFF, ATOS illumination ON/OFF
Dimensions
700 (W) × 740 (D) × 640 (H) mm
Weight
105 kg
Power Requirement
150 VA
Software
JASCO Spectra Manager ™ II
OS
Windows7 Professional
Program
Microscope Measurement (multi-point measurement, line and lattice mapping), Micro Spectra Analysis, Spectra Analysis (data processing such as ?lm thickness calculation, color calculation, peak detection, derivatives), Time-Course Measurement, Validation, JASCO Canvas, Administrative Tools
Program (Option) *3
Fixed wavelength mapping (line and lattice mode), auto focus, multi-image

*1. Cassegrain objective and cassegraing collection mirror are provided with the same magnification.
*2. The moving distance of the condensor mirror and the objective magni?cation depends upon the sample.
*3. Optional programs are provided when auto stage is selected.